Custom Retrofit Incentives
Multi-unit residential building
Building automation controls
Average incentive $31,0006 per project.
Use both software and hardware
to monitor and manage building
systems—such as heating and
ventilation systems—to ensure
maximum efficiency and reduce
energy use and costs.
Boiler optimization
Optimize the efficiency of boiler systems
to save energy and increase occupant
comfort. Take advantage of top-up incentives
for heating system assessments and
implementation incentives for improving
boiler performance.
Air-to-water heat pumps
Upgrade an air-cooled chiller to an ATWHP
while keeping your natural gas boiler for
backup heating. This increases heating
efficiency while ensuring cold
weather resiliency.
Office building
Ventilation controls
Average incentive $31,0006 per project.
Use both software and hardware
to monitor and manage building
systems—such as heating and
ventilation systems—to ensure
maximum efficiency and reduce
energy use and costs.
Steam and hot water systems
Optimize the efficiency of boiler systems
to save energy and increase occupant
comfort. Take advantage of top-up incentives
for heating system assessments and
implementation incentives for improving
boiler performance.
School's
Energy Recovery Ventilators
Provide fresh outdoor air while
recovering the most energy possible
from outgoing air.
Buildings without an ERV, where one is
not required by code
55 – 64% sensible heat
recovery effectiveness.........................$1.00/CFM
65 – 74% sensible heat
recovery effectiveness..........................$1.25/CFM
75 – 84% sensible heat
recovery effectiveness.........................$1.50/CFM
≥ 85% sensible heat recovery
effectiveness.........................$1.75/CFM
Buildings upgrading their existing ERV
system to a higher efficiency level
65 – 74% sensible heat
recovery effectiveness..........$0.50/CFM
75 – 84% sensible heat
recovery effectiveness.........................$0.75/CFM
≥ 85% sensible heat recovery
effectiveness ..............................................$1.15/CFM
Minimum $200 to maximum $8,000 per unit.
Energy Recovery Ventilators
Draw fresh, outdoor air to replenish the
air that has been pushed out through
exhaust systems.
Constant speed......................................$0.50/CFM
2 speed or VFD........................................$1.00/CFM
Minimum $750 to maximum $14,000 per unit.
Heat Recovery Ventilators
Keep heat in while moving stale air
out using a highly efficient heatexchange
core.
Buildings without an HRV, where one is
not required by code
55 – 64% sensible heat
recovery effectiveness........................$0.50/CFM
65 – 74% sensible heat
recovery effectiveness.........................$0.75/CFM
75 – 84% sensible heat
recovery effectiveness.........................$1.00/CFM
≥ 85% sensible heat recovery
effectiveness.........................$1.25/CFM
Buildings upgrading their existing HRV
system to a higher efficiency level
65 – 74% sensible heat
recovery effectiveness...........$0.25/CFM
75 – 84% sensible heat
recovery effectiveness........................$0.50/CFM
≥ 85% sensible heat recovery
effectiveness ............................................$0.75/CFM
Minimum $200 to maximum $5,000 per unit.
Hybrid rooftop units (RTU)
Use a heat pump for efficiency, with
natural gas backup for heating during
cold weather.
≤ 32 kBtu/hr..............................$1,000/unit
33 – 77 kBtu/hr......................................$2,500/unit
78 – 110 kBtu/hr.....................................$4,000/unit
111 – 200 kBtu/hr.....................................$8,000/unit
≥ 201 kBtu/hr...........................$40/kBtu/hr
Incentives based on hybrid RTU heating capacity.
Custom Incentive
Custom incentives may be available for hybrid
RTUs ≥ 201 kBtu/hr heating capacity. Your
Energy Solutions Advisor will let you know if
this applies to your project.